Description of the case
The coal pulverizer is applied to crush the coal to an average size of 0.074 mm powder. At the entrance of coal pulverizer, the temperature would be between 160 C to 393 C. The blowing speed is 50 to 55 m/second. When the high Cr cast steel (48-58 HRC) liner plate is used, the service life is 1.5 to 2 years, but spalling would be an issue. When the ceramic liner plate is used, the service life is extended, but the impact failure would be an issue. When the competitor's CCO plate is used, the impact resistance is improved, but service life is only 1 year. Now the Duroxite 100 is being tested in the field. The service life data will be updated soon.
-
0 – 250 °C / 32 – 480 °F
-
10 – 300 mm / 0.4 – 12.0 "
Old solution
Old solution
Thickness
Competitor's CCO, 10 mm + 10 mm
Service life
1 year
New solution
New solution
Duroxite® 100
Thickness
10 mm + 10 mm
Service life
under collecting
Key success factors
Improved service life